|
.: 02 Marzo - Symantec lanza nuevo "Patch 176" para SMS SMTP 5.0
Disponible para bajar en:
http://www.a10t.com/download/Patch176.zip
Descripcion e instrucciones de instalacion:
Contents of Patch 176:
----------------------
24412
Component: Installer
Platform: Windows only
Summary: Patch installer for Windows causes issues
Under some conditions the Windows patch installer caused the Registry
and the IIS metabase to become out of synch, resulting in a system that
exhibits the following symptoms:
- An "extra" IIS instance is created and started.
- The Control Center erroneously reports that all MTAs are stopped.
- It is no longer possible to control the IIS MTA instances from within the Control Center GUI.
Pre-Installation Steps for Scanner Only and Scanner/BCC Combo Machines
======================================================================
1. This patch ensures that the windows installer will no longer cause
the conditions described above. If your system is currently
experiencing those symptoms, you MUST perform the steps documented at
http://service1.symantec.com/SUPPORT/ent-brightmailkb.nsf/docid/2007021515455463
prior to installing this patch. If your systems are NOT currently
experiencing those symptoms, you may safely bypass this step.
2. If you have configured any new IIS virtual servers on the Scanner system
subsequent to installing SMSSMTP 5.0, these instances MUST be removed prior
to installing this patch. Open the Internet Services Manager. Find and
delete any SMTP virtual servers other than the Symantec embedded MTAs and
the default SMTP Server. If you have NOT configured any new IIS virtual
servers on the Scanner system, then you may safely bypass this step.
Installation Instructions
=========================
It is recommended that you set each Scanner that you are patching to
temporarily reject incoming connections. It is also recommended that
you drain the message queues before you apply this patch, unless the
issues addressed in this patch resolve problems with messages which
are currently stuck in the queues.
Draining your message queues
----------------------------
To stop delivery and drain a Scanner's message queue
1 In the Control Center, click Settings > Hosts.
2 Check the box next to the Scanner and click Edit.
3 Click Do not accept incoming messages.
4 Click Save.
5 Allow messages to drain from the queue.
You can check message queue status in Status > Message Queues.
To re-enable message delivery (do this after you have installed the patch)
1 In the Control Center, click Settings > Hosts.
2 Check the box next to the Scanner and click Edit.
3 Click Accept and deliver messages normally.
4 Click Save.
Installation
------------
To install the patch, follow these steps:
Windows:
Install instructions:
1. Download the patch installers for Scanner and Control Center.
2. Copy the Scanner patch installer to your Scanner machine(s) and the
Control Center patch installer to your Control Center.
3. Run the Control Center patch installer by double clicking the icon for
sms-smtp-bcc.msp
4. Run the Scanner patch installer by double clicking on the icon for
sms-smtp-scanner.msp
5. When the patch is installed, restart the machine.
Note: If you have both the scanner and the BCC running on a single machine,
copy both patch installers to that machine and run the Control Center patch
first, then the Scanner patch without rebooting the machine.
6. Restart the following services from the Control Center:
Filter Engine
Conduit
LiveUpdate
MTA
|